Test Code 8585 Lipid Panel
Purpose
Measuring cholesterol levels, as undesirable cholesterol levels places one at higher risk for coronary artery disease.
Performing Laboratory
Copley Hospital
Methodology
See individual test listings
Specimen Requirements
Specimen Type: Blood (Plasma or Serum)
Preferred: Light-Green Top
Acceptable: Gold Top
Specimen Volume: Full Tube
Specimen Minimum Volume: 2 mL
Collection Instructions:
1. Label specimen with patient’s full name, date of birth,
date & time of collection and person collecting.
2. If delay in specimen transport > 1 hour, centrifuge tube.
3. Refrigerate specimen during transport.
Reference Values
Cholesterol |
Desirable Level: < 200 mg / dL Marginally-High Risk: 200 - 239 mg / dL High-Risk: > 240 mg / dL |
HDL Cholesterol |
High Risk: < 35 mg / dL |
LDL Cholesterol |
Desirable: < 130 mg / dL Borderline: 130 - 160 mg / dL High Risk: > 160 mg / dL |
Triglycerides |
Normal: < 200 mg / dL High: 400 - 1,000 mg / dL Very High: > 1,000 mg / dL |
Stability
Refrigerated: 2 Days
Day(s) Performed
Daily
Available STAT
Analytical Time: 1 Day
Aliases
Lipid Panel
Lipoprotein Panel
Lipoprotein
Lipid
Test Classification and CPT Coding
80061